[1]邓智元、陈思坚.局部SRC二次转换结构受力性能研究[J].福建工程学院学报,2019,17(03):219-223.[doi:10.3969/j.issn.1672-4348.2019.03.003]
 DENG Zhiyuan,CHEN Sijian.Study on mechanical performance of local SRC secondary transfer structures[J].Journal of FuJian University of Technology,2019,17(03):219-223.[doi:10.3969/j.issn.1672-4348.2019.03.003]
点击复制

局部SRC二次转换结构受力性能研究()
分享到:

《福建工程学院学报》[ISSN:2097-3853/CN:35-1351/Z]

卷:
第17卷
期数:
2019年03期
页码:
219-223
栏目:
出版日期:
2019-06-25

文章信息/Info

Title:
Study on mechanical performance of local SRC secondary transfer structures
作者:
邓智元、陈思坚
福建工程学院土木学院
Author(s):
DENG ZhiyuanCHEN Sijian
School of Civil Engineering, Fujian University of Technology
关键词:
二次转换局部SRC转换梁应力集中扭转效应
Keywords:
secondary transfer local SRC transfer beam stress concentration torsion effect
分类号:
P315.97
DOI:
10.3969/j.issn.1672-4348.2019.03.003
文献标志码:
A
摘要:
提出在主次梁交接处至支座处加设型钢,形成局部型钢混凝土(steelreinforcedconcrete,SRC)二次转换结构。采用有限元法研究不同剪跨比下局部SRC二次转换结构的抗剪、抗扭、缓解应力集中能力,并与SRC二次转换结构、钢筋混凝土(reinforcedconcrete,RC)二次转换结构进行受力性能比较。结果表明:局部SRC二次转换结构能明显缓解应力集中和扭转效应不利因素,当剪跨比为0.65~1.90时,其抗扭、抗剪效果最佳。
Abstract:
A secondary transfer structure was proposed, which added section steel at the junction of orthogonal and secondary beams to the bearing, making up local SRC secondary transfer structures. Finite element method (FEM) was used to study the shear resistance, torsion resistance and stress concentration relief ability of the local SRC secondary transfer structures under different shear span ratios. These mechanical properties were compared with those of SRC secondary transfer structures and reinforced concrete’s secondary transfer structures. Results show that local SRC secondary transfer structures can effectively relieve the stress concentration and the torsion effect, and their torsion resistance and shear resistance effects are the best when the shear span ratio falls in the range of 0.65~1.90.

参考文献/References:

[1]施嘉奇. 落地剪力墙对带梁式转换层的框支剪力墙结构抗震性能影响分析[D]. 合肥: 合肥工业大学, 2018.[2] 金雪峰, 于彦召, 黄春杏, 等. 某超限高层住宅型钢混凝土框架转换结构设计[J]. 建筑结构, 2019, 49(5): 90-95.[3] 住房和城市建设部. 高层建筑混凝土结构技术规程: JGJ3-2010[S]. 北京: 中国建筑工业出版社, 2011. [4] 雷静. 带主次梁转换层框支剪力墙结构计算分析[D]. 西安: 长安大学, 2006.[5] 马斐. 基于体系能力设计法的某高位转换超限结构抗震性能设计[J]. 建筑结构, 2018, 48(5): 54-60. [6] LONDHE R S. Shear capacity of reinforced concrete transfer beams reinforced with longitudinal steel[J]. Journal of Structural Engineer, 2008,35: 190-194.[7] LI J H, SU R K L, CHANDLER A M. Assessment of lowrise building with transfer beam under seismic forces[J]. Engineering Structures, 2003, 25(12): 1537-1549.[8] 关立军, 张伟. 复杂框支转换结构抗震计算分析[J]. 建筑结构, 2009, 18(2): 9-18.[9] 王婧奇. 型钢混凝土抗扭构件非线性有限元分析[D]. 桂林: 桂林理工大学, 2010. [10]李国强, 崔大光, 李一松. 型钢混凝土梁柱框支剪力墙结构抗震性能试验研究[J]. 地震工程与工程振动, 2006, 26(2): 80-87. [11] 陆婷婷, 梁兴文, 胡翱翔, 等. 翼缘宽度对预期损伤部位采用FRC增强的梁柱组合件破坏机制影响的试验研究及数值模拟[J]. 土木工程学报, 2016, 49(12): 52-64.